FEM ConstraintHeatflux: Difference between revisions

From FreeCAD Documentation
No edit summary
m (docnav)
Line 1: Line 1:
<languages/>
<languages/>
<translate>
<translate>
{{docnav|[[FEM_ConstraintInitialTemperature|Constraint initial temperature]]|[[FEM_ConstraintTemperature|Constraint temperature]]|[[FEM_Module|FEM_Module]]}}

<!--T:1-->
<!--T:1-->
{{GuiCommand|Name=FEM ConstraintHeatflux|MenuLocation=Model → Thermal Constraints → Constraint heatflux||Workbenches=[[Fem Workbench|FEM]]|Shortcut=|SeeAlso=[[FEM_tutorial|FEM tutorial]]}}
{{GuiCommand|Name=FEM ConstraintHeatflux|MenuLocation=Model → Thermal Constraints → Constraint heatflux||Workbenches=[[Fem Workbench|FEM]]|Shortcut=|SeeAlso=[[FEM_tutorial|FEM tutorial]]}}
Line 24: Line 26:




{{docnav|[[FEM_ConstraintInitialTemperature|Constraint initial temperature]]|[[FEM_ConstraintTemperature|Constraint temperature]]|[[FEM_Module|FEM_Module]]}}
{{FEM Tools navi}}
{{Userdocnavi}}
</translate>
</translate>
{{clear}}
{{clear}}

Revision as of 19:59, 7 February 2019

FEM ConstraintHeatflux

Menu location
Model → Thermal Constraints → Constraint heatflux
Workbenches
FEM
Default shortcut
None
Introduced in version
-
See also
FEM tutorial

Description

This constraint specifies film heat transfer of a surface at temperature T and with a film coefficient h to the environment or sink at temperature T0 . The convective heat flux q will satisfy: q = h(T -T0)

Use

  1. Click on or choose ModelThermal Constraints Constraint heatflux from the top menu.
  2. Select in the 3D-view the surface(s) the constraint should be applied to.
  3. Enter the desired surface temperature, film coefficient and environment temperature.

Limitations

Notes

  1. The constraint uses the *FILM card in CalculiX. The heatflux constraint is explained at http://web.mit.edu/calculix_v2.7/CalculiX/ccx_2.7/doc/ccx/node203.html