FEM ConstraintHeatflux: Difference between revisions
Renatorivo (talk | contribs) (Created page with "<translate> <!--T:1--> {{GuiCommand|Name=FEM ConstraintHeatflux|MenuLocation=FEM → Constraint heatflux||Workbenches=FEM|Shortcut=|SeeAlso=FEM_tutorial|FE...") |
Renatorivo (talk | contribs) No edit summary |
||
Line 1: | Line 1: | ||
<translate> |
<translate> |
||
<!--T:1--> |
<!--T:1--> |
||
{{GuiCommand|Name=FEM ConstraintHeatflux|MenuLocation= |
{{GuiCommand|Name=FEM ConstraintHeatflux|MenuLocation=Model → Thermal Constraints → Constraint heatflux||Workbenches=[[Fem Workbench|FEM]]|Shortcut=|SeeAlso=[[FEM_tutorial|FEM tutorial]]}} |
||
==Description== <!--T:2--> |
==Description== <!--T:2--> |
||
This constraint specifies film heat transfer of a surface at temperature ''T'' and with a film coefficient ''h'' to the environment or sink at temperature ''T<sub>0</sub> ''. The convective heat flux ''q'' will satisfy: '''''q = h(T -T<sub>0</sub>)''''' |
This constraint specifies film heat transfer of a surface at temperature ''T'' and with a film coefficient ''h'' to the environment or sink at temperature ''T<sub>0</sub> ''. The convective heat flux ''q'' will satisfy: '''''q = h(T -T<sub>0</sub>)''''' |
||
==Use== <!--T:3--> |
==Use== <!--T:3--> |
||
#Click on [[Image:FEM ConstraintHeatflux.png|32px]] or choose {{KEY| |
#Click on [[Image:FEM ConstraintHeatflux.png|32px]] or choose {{KEY|Model}} → '''Thermal Constraints''' → {{KEY|[[Image:FEM ConstraintHeatflux.png|32px]] Constraint heatflux}} from the top menu. |
||
#Select in the 3D-view the surface(s) the constraint should be applied to. |
#Select in the 3D-view the surface(s) the constraint should be applied to. |
||
#Enter the desired surface temperature, film coefficient and environment temperature. |
#Enter the desired surface temperature, film coefficient and environment temperature. |
||
Line 14: | Line 16: | ||
==Notes== <!--T:5--> |
==Notes== <!--T:5--> |
||
#The constraint uses the *FILM card in CalculiX. The heatflux constraint is explained at http://web.mit.edu/calculix_v2.7/CalculiX/ccx_2.7/doc/ccx/node203.html |
#The constraint uses the *FILM card in CalculiX. The heatflux constraint is explained at http://web.mit.edu/calculix_v2.7/CalculiX/ccx_2.7/doc/ccx/node203.html |
||
Revision as of 08:40, 4 March 2018
FEM ConstraintHeatflux |
Menu location |
---|
Model → Thermal Constraints → Constraint heatflux |
Workbenches |
FEM |
Default shortcut |
None |
Introduced in version |
- |
See also |
FEM tutorial |
Description
This constraint specifies film heat transfer of a surface at temperature T and with a film coefficient h to the environment or sink at temperature T0 . The convective heat flux q will satisfy: q = h(T -T0)
Use
- Click on or choose Model → Thermal Constraints → Constraint heatflux from the top menu.
- Select in the 3D-view the surface(s) the constraint should be applied to.
- Enter the desired surface temperature, film coefficient and environment temperature.
Limitations
Notes
- The constraint uses the *FILM card in CalculiX. The heatflux constraint is explained at http://web.mit.edu/calculix_v2.7/CalculiX/ccx_2.7/doc/ccx/node203.html